This site uses cookies to offer you a better browsing experience. By continuing to navigate through this site or by clicking Approve, you consent to the use of cookies on your device as described in our privacy notice.
Speed Extractor E-916
Speed Extractor E-916

Speed Extractor E-916

Combine maximum speed and throughput

The SpeedExtractor is your best solution for fast Pressurized Solvent Extraction (PSE). Increase productivity by processing up to 6 samples in parallel. Streamline the workflow of your sample preparation thanks to ease of sample loading and ready-to-use extract collection.

What is the benefit of a parallel extraction/evaporation approach?

Concerted parallel extraction/parallel evaporation as opposed to a sequential approach increases the sample throughput and reduces the time to analysis significantly. An incoming batch of six samples is ready for the analysis after 115 minutes.

What is so convenient about the SpeedExtractor’s sealing system?

BUCHI’s unique extraction cell design is absolutely fail-safe, reliable and yields reproducible results. A lift mechanism automatically closes the cells at the push of a button. Hence, covering the sample with a filter paper is sufficient to make the sample ready for extraction.

Enquiry

Benefits

Unrivaled throughput

  • 6 times faster than other PSE instruments thanks to parallel extraction concept
  • Extract up to 96 samples in an 8 hour shift
  • Accelerate the extraction process and facilitate final results within one working day
  • Reduce number of replicates due to identical extraction conditions for up to 6 samples

Ease of operation

  • Unique design of extraction cells allows for ease of sample loading and cell assembly
  • High level of automation saves time-consuming preparation and increases safety
  • Quick, fail-safe and reproducible operation due to assembly of only 4 sample cell parts
  • The automated sealing eliminates sources of error and guaranties safety standard

Low running costs

  • Complementary workflow and synergy with parallel evaporation and concentration
  • Collection vessels with appendix make extract transfer obsolete
  • Reduced solvent consumption and minimal need for consumables give lower running costs
  • Save energy and costs with ECO mode for automated heater control

Features


 

Parallel workflow for high throughput

Significantly increase throughtput with the concerted parallel extraction and parallel evaporation. Full compatibility of the SpeedExtractor collection glassware with Syncore® Analyst and Multivapor™.


 

 

Automated sealing

The fail-safe and reliable extraction cells seal automatically using a unique sealing principle and guarantees reproducible results.


 

 

Reliable recording

SpeedExtractorRecord™ Software allows for managing and storage of methods, graphical visualization and documentation.


 

 

Wide application spectrum

The wide temperature a and pressure range b, sample volumes from 1 to 120 mL c and the integrated mixer for up to 4 solvents d allow to extract reliably complex matrices with high recovery e of the analytes.


 

 

Extraction made easy

The operation of the SpeedExtractor E-914 / E-916 is easy and intuitive. Apply an established method at the push of a button and extract simultaneously to up to 6 samples.


 

 

Highest flexibility

Extract your sample with optimized methods thanks to the flexible process parameters (30 - 200 °C; 50 - 150 bar) and the different extraction cells (E-916: 10, 20, 40 mL; E-914: 40, 80, 120 mL).


 

Voice of the customer

“SpeedExtractor is an exhaustive, reliable and quick system for the extraction of environmental samples. It speeds up and helps us during our sample treatment step.”

Dr S. Losada, Analytical Research Chemist CEFAS, location; Lowestoft, East Anglia, UK

Why does high pressure increase the extraction efficiency?

The combination of elevated temperature and pressure results in faster extraction compared to other extraction technologies. This is the result of an improved mass transfer because of higher analyte solubility and enhanced penetration. An increase from normal pressure pn to p2 is thereby necessary to keep the sample in the liquid state at T2.

Isn't there any chance of cross-contamination for adjacent positions?

Each position has its own inlet and outlet valve as well as individual pressure sensors. Even in case of blockage of one position cross-contamination is excluded as an integrated troubleshooting wizard automatically relieves the pressure. All other positions can be finished while the faulty position is deactivated.

Is a method which has been optimized for ASE directly applicable to the SpeedExtractor?

Yes! Slight modifications in the STATIC time (i.e. HOLD for the SpeedExtractor) might be necessary (usually shorter for the SpeedExtractor).


 

Collection racks for SpeedExtractor E-914/E-916

The SpeedExtractor integrates different collection options with great flexibility depending on the application and following step after extraction. Although SpeedExtractor is delivered with a comprehensive starter kit the way of extract collection need to be considered separately guaranteeing a perfect fit to the subsequent step after extraction.


 

Caps and septa

Reduce the risk of clogged needles or exhaust lines. The caps and septa optimally fit to the BUCHI collection vessels.

 

 

SpeedExtractorRecord Software

Software package allows for managing and storage of methods, graphical visualization of the extraction process and documentation through an electronic logbook. A single PC license for installation under Windows 8.1

Applications


 

Extraction Academia

For a wide range of applications in the scientific research as well as for academic education


 

 

Extraction Chemicals

Polymers: additives (plasticizers, stabilizers, etc.) / Contamination / Branching fraction Textiles: dyes / Residues: perfluorinated compounds (PFCs), phthalates, chlorinated paraffins, formaldehyde / Contaminants: pesticides, PCBs, PAHs


 

 

Extraction Food

Crude or total fat, lipids (after hydrolysis) / Contaminants: food, food contact materials, processing / Residues: pesticides, veterinary drugs / Flavors and odors


 

 

Extraction Environmental Analysis

Persistent organic pollutants (POPs) / Total petroleum hydrocarbons (TPHs) / Pharmaceuticals, personal care products (PPCPs) / Volatile organic compounds (VOCs) / Explosives


 

 

Extraction Pharmaceutical

Nutraceuticals / Herbal and dietary supplements / Plant toxins / Monitoring of active reagents


 

 

Extraction Feed

Crude fat, total fat


 

Technical Resources

E-916_E-914_Data_Sheet_en_B

Speed Extractor E-916

VIEW

WP_151-2014_HALS_in_Polyethylene

Speed Extractor E-916

VIEW

20150511_White_paper_natural_products

Speed Extractor E-916

VIEW

Whitepaper_Dioxin_and_PCB_in_foodstuff

Speed Extractor E-916

VIEW

BestBuchi_51_PAH_low

Speed Extractor E-916

VIEW

Contact Us at +9714 2152799

We can help you with a solution tailor to your specific need.