The modular FT-NIR spectrometer

The N-500 FT-NIR spectrometer provides reliable analysis results for quality control as well as research and development in the pharmaceutical, chemical, food, beverage and feed industry. The NIRFlex N-500 offers a wide range of measuring cells and accessories for highest performance.

What are my commercial benefits of using NIR spectroscopy?

Research and quality control laboratories benefit from NIRS alike. While researchers can accelerate their experimentation, QC departments benefit from the ability to analyze hundreds of samples per day – both saving substantial amounts of time and money.

How does a polarization interferometer work?

The heart of the interferometer consists of two bi-refringing crystal wedges. By moving one wedge, a part of the light undergoes a phase shift. This phase shift alters the polarization of the entire beam. After passing a polarization filter the interferogram is detected. All wavelengths are measured simultaneously.

Enquiry

Benefits

Reliable and flexible

  • Precise and accurate analysis results due to highest wavelength precision
  • Direct and effortless transfer of calibrations from instrument to instrument
  • Precisely analyzes different types of sample (solid, powder, tablet, granule, paste, liquid, etc.) by dedicated measuring options

Fast, safe and easy

  • Delivers results in seconds
  • Obtains several parameters simultaneously
  • No chemicals or solvents
  • User friendly and intuitive handling

Highly efficient

  • Fast analytical results allow rapid process optimization
  • Low cost of ownership as (common spare parts are user-exchangeable, no periodic instrument re-calibration required etc.)
  • Continuous operation due to the twin lamp safeguard

Features


 

The BUCHI polarization interferometer

BUCHI has adapted the successful quartz polarization interferometer by using crystals with a very high refractive index. This leads to optimum resolution and a compact design maintaining the advantage of insensitivity to mechanical disturbances. The reason for the superior performance of this interferometer in rough environments is the difference of spatial movements and the optical path shifts for the two light beams in a birefringent crystal of variable thickness. Whereas in a Michelson type interferometer mechanical distortions directly affect the interference, such effects are reduced by a factor of 10 to 20 in a crystal interferometer.


 

 

The twin lamp module

BUCHI has set a new standard in terms of the availability of an NIR spectrometer.Our NIR spectrometers are equipped with a twin lamp module, which will automatically switch to a second integrated lamp in the event of a failure of the primary source. This minimizes the risk of an instrument failure, and sufficient time is left to order a replacement lamp. Meanwhile you can continue your measurements without further intervention.


 

 

The integrated standards

Each BUCHI FT-NIR spectrometer is equipped with various gray filters and a wavelength standard. They enable wavelength accuracy, signal-to-noise ratio, and linearity to be checked using specially designed software modules. These measurements form the System Suitability Test (SST), which is indispensable in the pharmaceutical industry in order to meet regulations.


 

Additional features


 

NIR Applications Finder

Quickly find relevant precalibration details and expected performance for your application using the on-line NIR applications finder.


 

Do I need to calibrate my BUCHI FT-NIR spectrometer?

There is no need for instrument calibration. The term “calibration” is used in NIR with two different meanings:

  • Unlike other NIR instruments, the BUCHI instrument does not need to be calibrated since the accuracy is ensured by internal standards and permanent laser-aided alignment.
  • In NIR spectroscopy a calibration model is generally required to interpret sample data. This model needs to be developed on setup of the application. BUCHI’s NIRCal software makes it straight forward to develop robust and reliable calibrations by correlating NIR data with reference analytics.

Can NIR spectroscopy completely replace reference analytics?

Replace completely the reference analytics is not the target. NIR spectroscopy is a powerful technique to rapidly and reliably screen samples and therewith eliminate a lot of routine analysis. A limited amount of reference analysis is still needed to develop the initial calibration models and to periodically verify their performance.

How many parameters can be analyzed simultaneously?

While the number of parameters measurable within a calibration model is only limited by computing power and complexity of the analysis, it is common to analyze 15-30 properties at the same time.

What is the optimal resolution for an NIR Spectrometer?

For modern instruments 8 cm-1 resolution is optimal for NIR measurement. As NIR spectral bands are relatively broad, higher resolutions do not improve the performance of NIR application. On the contrary, higher resolution spectra have a poorer signal-to-noise ratio within a given measurement time.


 

NIRFlex N-500 with Solids Cell N500-001

Measurement of powder, solid, granules and cream samples in diffuse reflectance mode or liquids and suspensions in transflectance mode.


 

NIRFlex N-500 with Liquids Cell N500-002

Measurement of clear liquids in transmission mode. Possibility to work with cuvettes of 1, 2, 5 and 10 mm path lengths, as well as disposable vials. The configuration allows multiple samples measurement sequence up to 6 positions.


 

NIRFlex N-500 Fiber Optic SMA Cell N505-000

Cell for reflectance as well as transmission measurement. Possibility to plug separate probes and fiber optic cables.


 

NIRFlex N-500 with Solids Transmittance Cell N500-010

Measurement of solid samples like capsules and powders in diffuse transmission. Various sample plates are available to fit tablets with a wide range of size and shapes.


 

NIRFlex N-500 with Fiber Optic Solids Cell N500-007

On-site raw materials control for powders, granular materials, solids and creams in diffuse reflection mode, as well as liquid samples in transflectance mode

Applications


 

NIRSolutions Feed and Forage

Test raw materials, premixes and finished products for

  • moisture
  • fat
  • protein
  • ash and fiber
  • ADF and NDF
  • amino acids

 

 

NIRSolutions Academia

Make new discoveries with BUCHI NIRSolutionsTM. We support the researchers efforts with flexible products coupled with our application expertise.


 

 

NIRSolutions Chemical

Control processes by

  • raw material qualification
  • hydroxyl number measurement
  • polymerization end-point determination
  • residual moisture/ solvent quantification

 

 

NIRSolutions Pharma

Perform regulatory compliant

  • raw material identification and/or qualification
  • tablet content uniformity analysis
  • final product release testing

 

 

NIRSolutions Environmental Analysis

Customize accurate calibrations to measure

  • moisture, organic carboon and total nitrogen content of soils
  • fertilizers formulation
  • biogas potential of biodegadable feedstock and urban waste

 

 

NIRSolutions Food and Beverage

Control dairy, meat, milling and other food products for

  • moisture
  • macronutrients
  • ash and fiber
  • rheological properties

 

Technical Resources

NIRFlex_N500_DS_A4_en_D

NIR Flex

VIEW

bestbuchi_56_Calibration_transfer_NIR_Checkmaster_0

NIR Flex

VIEW

bestbuchi_019_NIR_Nutrition_B_0

NIR Flex

VIEW